Wide range of pore sizes and high compatibility with 100% aqueous phases make Bio-C18 columns ideal for high resolution mapping of peptides and separation of natural and synthetic peptides and small proteins. The specially designed surface bonding chemistry and the pore sizes allow for extended retention and selectivity for polar and hydrophilic compounds, such as peptides and amino acids. C18 monolayer formed by special bonding chemistry does not collapse in pure aqueous solution.
Silica:
Sperical, high purity (<10 ppm metals)
Pore size:
200 Å
Particle size:
3, 5, and 10 µm
Pore volume:
1.0 ml/g
Surface area:
200 m²/g
Phase structure:
Monomeric and fully endcapped
% Carbon:
10%
Silica:
Spherical, high purity (<10 ppm metals)
Pore size:
300 Å
Particle size:
3, 5, and 10 µm
Pore volume:
0.95 ml/g
Surface area:
105 m²/g
Phase structure:
Monomeric and fully endcapped
% Carbon:
7%
Highly controlled chemistry of monolayer formation and end-capping
High column-to-column reproducibility
High selectivity and high efficiency for separations
Compatible with 100% aqueous mobile phase
Suitable for separations of peptides, proteins, and pharmaceuticals
[1] Guard column [2] Guard Cartridge only. [3] Guard Cartridge with holder. [4] One-piece PEEK coupler, recommended to connect columns in series. [5] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [6] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [7] 0.5 µm PEEK frit for column with particle size 3 µm or less [8] For Precolumn Filter (0.5 µm) 5 units/pk
[1] Guard column [2] Guard Cartridge only. [3] Guard Cartridge with holder. [4] One-piece PEEK coupler, recommended to connect columns in series. [5] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [6] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [7] 0.5 µm PEEK frit for column with particle size 3 µm or less [8] For Precolumn Filter (0.5 µm) 5 units/pk
[1] Guard column [2] Guard Cartridge only. [3] Guard Cartridge with holder. [4] One-piece PEEK coupler, recommended to connect columns in series. [5] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [6] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [7] 2 µm PEEK frit for column with particle size 5 µm and 10 µm. [8] Intended for use with column IDs ≥ 21.2 mm [9] For Precolumn Filter (2 µm) 5 units/pk [10] SS Refill Frits for 102020-21200, 5 units/pk
[1] Guard column [2] Guard Cartridge only. [3] Guard Cartridge with holder. [4] One-piece PEEK coupler, recommended to connect columns in series. [5] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [6] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [7] 2 µm PEEK frit for column with particle size 5 µm and 10 µm. [8] Intended for use with column IDs ≥ 21.2 mm [9] For Precolumn Filter (2 µm) 5 units/pk [10] SS Refill Frits for 102020-21200, 5 units/pk
[1] Guard column [2] One-piece PEEK coupler, recommended to connect columns in series. [3] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [4] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [5] 2 µm PEEK frit for column with particle size 5 µm and 10 µm. [6] Intended for use with column IDs ≥ 21.2 mm [7] For Precolumn Filter (2 µm) 5 units/pk [8] SS Refill Frits for 102020-21200, 5 units/pk
[1] Guard column [2] One-piece PEEK coupler, recommended to connect columns in series. [3] PEEK/Stainless Steel coupler, recommended to connect columns of IDs > 7.8 mm in series. [4] Column coupler with 10cm length flexible tubing,10-32 fitting with 1/16 OD PEEK tubing. Recommended to connect analytical columns in series [5] 2 µm PEEK frit for column with particle size 5 µm and 10 µm. [6] Intended for use with column IDs ≥ 21.2 mm [7] For Precolumn Filter (2 µm) 5 units/pk [8] SS Refill Frits for 102020-21200, 5 units/pk